steam boiler for chemical textile industrial biomass steam boiler

Steam Systems in Industry: Energy Use and Energy Efficiency ... - aceee
we only had infonnation on biomass and waste fuel use in the major energy intensive indu

Details


  • Production capacity: 20-75 t/h
  • Work pressure: 1.25-5.4 MPA
  • Applicable fuel: Bituminous coal,biomass
  • Applicable industry: Power generation, heating, chemical, food, rubber


Product introduction

  DHL corner tube boiler is field assembled boiler, it uses a piping system as the frame of the entire boiler, and it bears the full load of the boiler, which makes a non-framework boiler. At the same time, this frame also serves as the down comer of the boiler and upper and lower headers. The boiler drum is an external type drum, the furnace is a fully enclosed membrane wall structure, the convective heat absorbing surface adopts the flag tube structure. The corner tube boiler has the advantages of compact structure, low steel consumption and rapid temperature increase.


Quick inquiry:
I need the quotation of , the fuel is , this capacity is , the pressure is , use for . My Name is , my Email is , my phone number is , Please Send the detail information for me!






Safe water circulation
  • The boiler adopts a unique water circulation structure; the drum is not heated and the heated water flows in one direction. In the event of power cut, the water does not vaporize in water system and the water circulation is safe and reliable.

Anti-seismic Structure
  • Corner tube boiler adopts non-framework structure, its body weight is supported by membrane wall and down comer, and all membrane walls are welded into one whole piece with good anti-seismicity.

Complete sealed structure
  • The boiler proper is surrounded by welded membrane wall, and the steel structure is completely sealed to prevent air leakage. The upper part of the boiler can be separately transported according to the size of the railway transportation limit. The excess air coefficient at the boiler tail is less than 1.2, which not only reduces the heat loss of the exhaust smoke and power consumption of the induced draft fan, but also greatly reduces the environmental pollution of the boiler house.

Model Rated thermal power t/h Rated working pressure MPA Rated imported water ℃ Design efficiency %
DHL35-1.25-AⅡ 35 1.25 194 89
DHL50-1.25-AⅡ 50 1.25 194 89
DHL75-1.25-AⅡ 75 1.25 194 89
ZZ-35/3.82-AⅡ 35 3.82 450 89
ZZ-50/3.82-AⅡ 50 3.82 450 89
ZZ-65/3.82-AⅡ 65 3.82 450 91
ZZ-75/3.82-AⅡ 75 3.82 450 91
ZZ-75/5.3-AⅡ 75 5.3 485 91

CONTACT FORM